Load Cell L6C aluminium single point

Features:

Cable type: Shielded, 6 conductor cable , conductor AWG 24
Cable diameter: Ø 6.2mm
Cable length: 3.0m ± 0.1m
Cable jacket: PVC
Shield not connected to element

CAPAcITIES

– 3kg – 5kg – 8kg – 20kg – 30kg – 50kg

Description

Load Cell L6C aluminium single point

  • Aluminium-alloy IP65 single point load cell
  • Colourless anodized
  • Available with flat ribbon or PVC cable
  • Suitable for counting and other electronic scales
  • Maximum platform size: 350 x 450 mm

Additional information

SPECIFICATIONS

Accuracy Class = C3
Output Sensitivity (FS) = mV/V 1.9 ± 0.2
Maximum Capacity (Emax) = 3kg, 5kg, 8kg, 20kg, 30kg, 50kg
Max. Number of Load Cell Intervals (nLC) = 3000
Ratio of min. LC Verification Interval (Y = Emax / vmin) = 7000
Combined Error (%FS) = ≤± 0.023
Creep Error (30 minutes) (%FS) = ≤± 0.0245
Temperature Effect on Zero (ZTC) (%FS/10°C) = ≤± 0.014
Temperature Effect on Sensitivity (STC) (%FS/10°C) = ≤± 0.0175
Zero Balance (%FS) = ≤± 2.0
Safe Overload (%FS) = 120
Ultimate Overload (%FS) = 150
Maximum Deflection (mm) = 0.62
Eccentric Loading Error (%Ld/cm) = ± 0.002
Excitation, Recommended Voltage (V) = 5 ~ 15
Excitation, Maximum Voltage (V) = 18
Input Resistance (Ω) = 406 ± 6
Output Resistance (Ω) = 350 ± 3
Insulation Resistance (50V) (MΩ) = ≥5000
Compensated Temperature (°C) = -10 ~ +40
Operating Temperature (°C) = -35 ~ +65
Storage Temperature (°C) = -40 ~ +70
Load Cell Weight (kg) = 0.39
Element Material = Aluminium
Ingress Protection (acc. to EN 60529) = IP65
Recommended Torque on Fixation Bolts (Nm) = M8: 20

Brand

ZEMIC

Reviews

There are no reviews yet.

Be the first to review “Load Cell L6C aluminium single point”

Alamat email Anda tidak akan dipublikasikan. Ruas yang wajib ditandai *

Related Products