DC type dynamic strain amplifier DAS-406B
Feature
  • DC to 200 kHz frequency range
  • Standard equivalent strain amplifier with four digit digital switch setting
  • 3 1/2 digit digital display
  • Specifications
Specifications
Measuring point 1 point / 1 unit
Applicable gage resistance 60 ohm to 1k-ohm
Gage factor 2.00
Bridge power supply DC2 V(Changeable to DC1 V, 4 V and 10 V)
with remote sensing function(50 mA or less)
Resistance balance adjustment range Approx. ±1 %
(Gage resistance 120 ohm, Approx. ±5 000x10-6 in strain)
Auto balancing Auto balance time Approx.1 s,
Accuracy ±0.1 %F.S.
Sensitivity 0.5 V output at the input of 100 x 10-6 in strain
(With bridge power supply at DC2 V)
Output MONITOR ±10 V, ±5 mA (Load resistance 2 k-ohm or more)
OUTPUT ±10 V, ±30 mA (Load resistance 330 ohm or more)
Output resistance 10 ohm or less
Output capacitive load 0.1 micro-F or less
Non-linearity ±0.01 % F.S.
Standard equivalent strain(CAL) Set with digital switch
±1 to ±9 999x10-6 in strain,
Accuracy ±0.2 %F.S. or less at each point
Sensitivity adjustable range(ATT) 1, 1/2, 1/5, 1/10, 1/20, 1/50, 1/100, 0
Accuracy ±0.2 %F.S. at each point
GAIN volumu valiable range
1 to 1/2.5 times continuous variable (VAR)
Frequency response range DC to 200 kHz +1 dB, -3 dB (Filter at W/B)
Low-pass filter 10 Hz, 100 Hz, 1 kHz, 10 kHz, W/B Third bessel type
S/N ratio 46 dBp-p(ATT=1) with W/B condition
55 dBp-p with 10 Hz to 10 kHz
Display Output voltage display 0.00 to ±10.00
Digital display (Green LED)
Sampling Approx.4 times/s
0.00 or -0.00 flashes when output voltage is in non-linear zone
Temperature efficient Zero shift ±0.1x10-6 in strain / 'C
Sensitivity variation ±0.01 %F.S./ 'C
Efficient due to time Zero shift ±5x10-6 in strain / 8 h
Sensitivity variation ±0.05 %F.S./8 h
Efficient due to power supply Zero shift ±1x10-6 in strain / variation of power supply voltage within ±10 %
Sensitivity valliation ±0.01 %F.S.
/variation of power supply voltage within±10 %
Operating temp./humidity range Temperature :-10'C to 50'C, Humidity 85 %RHor less (Non condensing)
Power supply voltage AC100 V±10 V, DC12 V 50/60 Hz
Power consumption Approx. 10 VA(at AC100 V), Options DC12 V Approx. 0.8 A
Outline dimensions(WxHxD) 42 mmx176 mmx284.4 mm(excludes protruding parts)
Weight Approx. 1.5 kg

Dynamic strain amplifier DSA - 631

Feature

  • Eqquipped with wire length compensating function and open circuit check function.
  • High sensitivity and high gain
  • Excellent visibility and operation
  • Dual power supply types
  • Specifications
Specifications
Measuring point 1 point per 1 unit
Applicable gage resistance 60 ohm to 1k-ohm
Gage factor 2.00
Bridge power supply AC0.5 V, 2 V, 5 kHz sine wave, Sync input/output signal 2.5 VAC
Balance adjusting range Deviation of resistive value : Approx. ±2 % (±10 000x10-6 in strain)
Capacitive imbalance : Approx. 2 000 pF
Balance adjusting Accuracy ±0.4x10-6 in strain (RANGE=200, without FINE, BV=2 V)
Maximum input range ±200 000 x 10-6 in strain (RANGE=20k, FINE=x2.5, BV=0.5 V)
Voltage sensitivity ±10 V within ±200 x 10-6 in strain
Shift of measuring range 200, 500, 1k, 2k, 5k, 10k, 20k (x10-6 in strain, x2/BV in value), OFF
Fine adjustment continuously changeable in FINE ~ RANGE
2 steps changing amount can be selected.
Non-linearity ±0.1 %F.S.
Standard equivalent strain(CAL) Set by digi-switch : ±1 to 9 999 x10-6 in strain
Accuracy ±0.5 %rdg+0.5x10-6 in strain
Frequency response range DC to 2 kHz±10 %
Hi-pass filter 0.5 Hz : 2-pole butterworth type
(Filter descent response : -12 dB/oct)
Low-pass filter 10 Hz, 30 Hz, 100 Hz, 300 Hz, 500 Hz : 4-pole butterworth type
(Filter descent response : -24 dB/oct)
Stability  
Temperature efficient Zero drift : Within ±0.1x10-6 in strain /'C
Sensitivity : Within ±0.05 %F.S./'C
Efficient due to time Zero drift : Within ±0.5x10-6 in strain /24 h
Sensitivity : Within ±0.2 %F.S./24 h
Noise 2.0 x10-6 in strain p-p RTI
(W/B, RANGE=200, Without FINE, BV=2 V, 120 ohm in bridge)
0.6 x 10-6 in strain p-p RTI
(DC=100 Hz, RANGE=200, Without FINE, BV=2 V, 120 ohm in bridge)
Output OUTPUT1 ±10 V, ±5 mA
OUTPUT2 ±10 V, ±10 mA
Output impedance 0.5 Ω or less,
Capacitive load Operable up to 0.1 μF
Output adjustment OUTPUT2 ADJ
(Can be independently varied continuously from 1 to 1/10)
Operating temp./humidity range Temp. -10'C to 50'C,
Humidity 20 % to 85 %RH or less(Non condensing)
Power supply voltage, Power consumption AC85 V to AC132 V/AC180 V to AC264 V
(Internal switch must be changed) 9 VA or less
DC10 V to DC30 V, 6 VA or less
Outline dimensions
(W x H x D)
49.5 mm x 143 mm x 253 mm (excludes protruding parts)
Weight Approx. 1.35 kg

Precision Calibrator PSC-350

Feature

  • 350 ohm precision calibrator
  • Output calibrated by connecting this unit with a digital indicator, etc., for the strain gage based transducer.
  • Specifications
Specifications
Rated output 0.5 mV/V range 10 steps
2 mV/V range 10 steps
5 mV/V range 10 steps
10 mV/V range 10 steps
Error

0.02 %F.S. (Temperature range from 15'C to 25'C)

Excitation, maximum DC 12V
Zero balance ±0.001 mV/V
Input resistance 350Ω ±7Ω
Output resistance 350Ω ±7Ω
Temp. effect on zero 0.03 %F.S. / 10'C
Temp. effect on output 0.03 %F.S. / 10'C
Operating temp./humidity range Temperature 0'C to 50'C, Humidity85%RH or less(Non condensing)
Outline dimensions(WxHxD) 185mm x 47mm x 125mm (excludes protruding parts)
Weight Approx. 1.3kg

Static Strain Digital Indicator PSD-704

Feature

  • Indicator for strain gage or strain gage applied transducer.
  • Check strain gage based transducers in mV/V.
  • Measure I/O resistance of strain gage based transducers. Insulation resistance measurement between load cell body and each cable wire is also available.
  • Applied RS-232C interface as a standard.
  • Specifications
Specifications
Bridge power supply DC 2V±0.02 V Within 35 mA
Target for measurement Strain measurement, Measurement on output of strain gage applied transducer, Meadurement on resistance value.
Measuring method Deflection method
(under measuring on strain or output of strain gage application)
Temperature efficient Zero point ±0.2 x 10-6 in strain/'C, Sensitivity ±0.01 %F.S./'C
(After 15 min. of warming up time with the range of x1)
Efficient due to time

Zero point ±0.2 x 10-6 in strain/8 h, Sensitivity ±0.01 %F.S./8 h
(Temperature variation within ±2'C with the range of x1)

A/D sampling 4 times/s
Display Dot matrix type liquid crystal display (with back light LED type)
Specification for strain measurement  
Measuring method 1 gage 2 wire method
Strain Gage : 120 ohm, 240 ohm, 350 ohm
1 gage 3 wire method
Strain Gage : 120 ohm, 240 ohm, 350 ohm
2 gage method
Strain Gage : 60 ohm to 1 000 ohm
4 gage method (Strain gage applied transducer)
Strain Gage : 60 ohm to 1 000 ohm
Measuring range x1 range : ±40 000 x 10-6 in strain
4GH range : ±3.500 0 mV/V
(±7 000.0 x 10-6 in strain)
(4 gage method, Only for strain gage applied transducer)
Resolution x1range : 1 x 10-6 in strain
4GHrange : 0.000 1 mV/V (0.1x10-6 in strain)
(4 gage method, Only for strain gage applied transducer)
Accuracy x1range : ±0.08 %F.S.±1 digit
4GHrange : ±0.08 %F.S.±2 digit
(4 gage method, Only for strain gage applied transducer)
Operating temp./humidity range Temperature 0'C to 50'C, Humidity 85 %RHor less(Non condensing)
Power supply voltage AC90 V to 132 V (in the usage of AC adapter) 50/60 Hz
or battery drive by Ni-Cd battery.
Power consumption Approx. 0.8 VA (When AC adapter is used.)
Outline dimensions(WxHxD) 210 mmx148.5 mmx40 mm (excludes protruding parts)
Weight Approx. 1.7 kg